Building Performance Knowledge Community

 View Only

Community HTML

Looking up at Buildings and Sky

Quick Links

Who we are

The mission of the Building Performance Knowledge Community (BPKC) is to increase building performance related to occupant comfort and health, and to the function, durability, sustainability, and resilience of buildings.
Learn more about our mission and goals >

Expand all | Collapse all

"Details Forum"

  • 1.  "Details Forum"

    Posted 05-12-2019 05:27 PM
      |   view attached
    The "Details Forum" is a major project in 2019 of the Building Performance Knowledge Community (BP-KC).

    The objective is to provide online information that shares good details among architects via a web location within the BP-KC site.  Another focus is to provide a vehicle for publicizing the activities of technically-oriented architects.

    A draft detail of a Parapet has been prepared as a test case for implementing a first draft of the "Details Forum." 
    See the attachment. 

    Stay tuned for this first draft to be published soon.

    Project participants are:
    Brad Gellert (lead)
    Stephen Katz
    Drake Wauters


    ------------------------------
    Joseph Deringer AIA
    Institute for Sustainable Performance of Buildings
    Berkeley CA
    ------------------------------

    Attachment(s)



  • 2.  RE: "Details Forum"

    Posted 05-14-2019 04:05 PM

    Thanks for the message about the start of the Details Forum. What a great idea. And an excellent example as the inaugural article about parapet thermal performance. Thanks to Payette for sharing their research and analysis. Very thoughtful way to address a common issue. We have had concerns about building a parapet on top insulation, perhaps crushing the insulation material and reducing its effectiveness. However, the simple approach of inserting insulation within the framing at the level of the roof insulation is a good approach. Thanks, again.

    Sherman Aronson

     
     
    Sherman C. Aronson, AIA, LEED AP BD+C
    Senior Associate
     
        
       
    1216 Arch Street
    Philadelphia, PA  19107‑2835
    Tel: 215 563 3900 Ext: 124
    www.BLTa.com
     
     
     


    NOTICE
    THIS E-MAIL, INCLUDING ANY ATTACHMENTS, IS CONFIDENTIAL AND FOR THE INTENDED RECIPIENT ONLY. IT MAY BE LEGALLY PRIVILEGED AND PROTECTED FROM DISCLOSURE. NOTHING IN THIS E-MAIL GRANTS ANY LICENSE OR TRANSFERS ANY OWNERSHIP OR ANY INTELLECTUAL PROPERTY RIGHTS TO THE RECIPIENT. IF THE READER OF THIS MESSAGE IS NOT THE INTENDED RECIPIENT, YOU ARE INFORMED THAT ANY DISSEMINATION, COPYING OR DISCLOSURE OF THE MATERIAL CONTAINED HEREIN, IN WHOLE OR IN PART, IS STRICTLY PROHIBITED. IF YOU HAVE RECEIVED THIS INFORMATION IN ERROR, OR ARE NOT THE INTENDED RECIPIENT, PLEASE NOTIFY THE SENDER IMMEDIATELY AND PURGE THIS MESSAGE. INTERNET COMMUNICATIONS CANNOT BE GUARANTEED TO BE SECURE, VIRUS-FREE OR ERROR FREE. BLT ARCHITECTS ACCEPTS NO LIABILITY FOR ANY LOSS OR DAMAGE FROM THE USE OF THIS E-MAIL.







  • 3.  RE: "Details Forum"

    Posted 05-16-2019 07:44 AM
    I have a retail client interested in trying frost protected shallow foundations for their stores.  Can anyone tell me of someone who does them regularly so we can learn from them and develop some confidence?
    William J. DeVos
    APD Engineering and Architecture
    237 Rockingham Street
    Rochester, NY   14620
    (585) 435-0364
    <rflbilldevos@gmail.com>





  • 4.  RE: "Details Forum"

    Posted 05-17-2019 05:36 PM
      |   view attached
    We have done them. The American Society of Civil Engineers has a "Design and Construction of Frost-Protected Shallow Foundations". See attached. Your air freezing index is probably similar to mine. I recommend a civil or structural engineer for the foundation design.

    ------------------------------
    Mike Sealander AIA
    Sealander Studio
    Brooklin ME
    ------------------------------

    Attachment(s)

    pdf
    ShallowFndn.pdf   1.67 MB 1 version


  • 5.  RE: "Details Forum"

    Posted 05-18-2019 07:20 AM
    Wow Mike, Thank you.  i was doubtful i'd get a response.  I am familiar with the ASCE guide, but it's great to see your marked up copy!  Would it be possible we could talk sometime more about your experience and what engineers you've used?  i have two geotechs who have had only a little experience and less with structural and civil.


    William J. DeVos
    APD Engineering & Architecture
    237 Rockingham Street
    Rochester, NY   14620
    (585) 435-0364
    <rflbilldevos@gmail.com>





  • 6.  RE: "Details Forum"

    Posted 05-20-2019 06:43 AM
    ​I did this one time for an exterior application that needed frost protection but had too many buried utilities on the site. It worked. It is a very interesting concept that should work.

    Our neighbors to the north are the experts in this area I believe. Perhaps it would be useful to contact the Canadians.

    ------------------------------
    Paul Johnson FAIA
    SmithGroup
    Detroit MI
    ------------------------------



  • 7.  RE: "Details Forum"

    Posted 05-20-2019 08:26 AM
    Thank you Paul, it's good to hear of your success too and that's a really good idea to look to the Canadians.  I'll see what i can learn.

    Thank you, Bill.
    William J.  DeVos, AIA
    Senior Architect
    APD Engineering & Architecture, PLLC
    615 Fishers Run, Victor, New York 14564
    T:  585.484.1302
    ǀ M:  585.435.0364 

    <rflbilldevos@gmail.com> <wdevos@apd.com>





  • 8.  RE: "Details Forum"

    Posted 05-24-2019 12:10 PM
    I think a Section here on building details is a great idea and the parapet, a very common problem area, is a perfect place to start.  The details presented compare two routes for the thermal barrier to follow at the parapet.  The discussion suggests that short-cutting the thermal barrier across the base of the parapet will have the advantage of reducing the total surface area of heat-transmitting wall exposed to the exterior. The proposed thermal shortcut uses spray foam inserted between the metal studs.  Some things to consider:

    1.     The vertical studs penetrate the spray foam so the R-value of the foam has to be de-rated accordingly.

    2.     To place the spray foam as shown would require a horizontal sheet "backer" closing off the space between studs.  The detail does not show what the backer material might be or how it would be held in place.  Often, vertical studs are doubled around openings and close-packed at corners multiplying the labor and practical problems of placing the backer and the foam.

    3.     Placing the spray foam: Is it placed from below via long nozzle inserted up behind the beam?  Installers have told us this is not practical.  Placed from above before the parapet is sheathed?  This can create construction sequence issues.

    4.     But the most unpredictable risk is the possibility of condensation forming in the un-vented, un-tempered, space above the foam.

    The discussion assumes the necessity of a parapet.  If optimum thermal performance is a goal, then early design discussions should question this necessity.

    ------------------------------
    Alan Swift AIA
    Director, Design Integration
    dbHMS Design Build Engineering
    Chicago IL
    ------------------------------



  • 9.  RE: "Details Forum"

    Posted 05-30-2019 11:44 AM
      |   view attached
    Hi everyone, this is a great discussion one which I can help with feedback. I rarely build these days, I was/am a licensed builder with a carpentry trade background, so I have a bit of an idea what's going on.
     I am in Australia and I know that a lot of our building regulations and methodologies overlap, so I thought it may be of some interest to see a few details that I created. I do all of my details in 3D, I actually animate them in Sketchup so our subcontractors get it right the first time. Here is an example https://3dlibrary.rubysketch.com/entries/pronto-panel-3d-residential-detail
    I've attached a 3D model, you can open it in Chrome or Internet Explorer. FYI. The attached 3d file is my method of communication these days, I have pretty much given up on paper; I no longer share plans, 3D models & more importantly IP, I only send the detail they need to get the job done.  

    There are plenty of details if you care to look, I would be interested in hearing your thoughts.
    Regards Andrew Dwight
    BTW I will be attending the AIA conference in Vegas next week, so if you hear and Australian accent, come and say G'day. B)


    ------------------------------
    Andrew Dwight
    Designer/BIM manager AAD Build
    Sydney Australia
    ------------------------------



  • 10.  RE: "Details Forum"

    Posted 06-04-2019 09:53 PM
    Hi Alan,  
    Thanks for the great comments you seem to be the only person in this discussion who noticed the condensation issue, so I'll direct my response to you (though it would be nice if others addressed the topic of the OP).  The detail attachment file stated that "The question with the non-Dow details, is there a danger of condensation occurring in the cavity in the parapet wall above the insulation level?"  It looks to me like the non-Dow detail has an unlabeled layer of 5/8" thick sheathing material continuous on back side of the parapet.  That looks like a potential path for vapor transmission into the cavity.  Do you think it would help to break the continuity of the layer like they do in the Dow detail?

    ------------------------------
    Richard Linsky AIA
    Project Architect
    Jacobs/Wyper Architects, LLP
    Springfield PA
    ------------------------------



  • 11.  RE: "Details Forum"

    Posted 06-05-2019 01:37 PM
    The idea of sharing and discussing details is great!

    I do have another comment on the parapet details: I do not find a clear indication of the continuity of the air barrier on these details.  Certainly, making sure we have continuous thermal insulation is important, but if there is air leakage at the roof/wall intersection, then the thermal barrier is compromised and moist air will condense where we don't want it.  
    • For the wall, spay foam insulation can serve as an air barrier, but how does it transition to membranes?  What happens when we use rigid foam insulation boards instead of the spray foam?
    • For the roof, do we want the single-ply membrane to serve as the air barrier, or are we using a air/vapor retarder membrane below the roof insulation to serve this purpose?  In either case, how are penetrations sealed?
    • And then, how does the roof air barrier meet the wall air barrier?


    ------------------------------
    Margaretha Eckhardt AIA, CSI, CCS, LEED AP
    Payette Associates, Inc.
    Boston MA
    ------------------------------



  • 12.  RE: "Details Forum"

    Posted 06-05-2019 07:20 PM
    @Margaretha E. Eckhardt AIA Member Emeritus ​, Great point - I was wondering the same thing.  A detail like this should clearly indicate the various barriers and their continuity.  Unfortunately, the detail in the attachment doesn't provide enough information.

    ------------------------------
    Richard J. Linsky, AIA, CSI, CDT, NCARB
    Project Architect
    Jacobs/Wyper Architects, LLP
    Philadelphia, PA
    ------------------------------



  • 13.  RE: "Details Forum"

    Posted 06-30-2019 07:04 PM
      |   view attached
    Here is an international take on a parapet detail. This project is in China. We were able to work closely with the LDI to improve their standard parapet details. Continuity of both insulation and the weather barrier from the roofing system to the window system over the parapet was the big challenge.

    ------------------------------
    Stephen Katz, AIA, LEED AP BD+C
    Gensler
    ------------------------------

    Attachment(s)

    pdf
    Parapet_Detail_1.pdf   277 KB 1 version


  • 14.  RE: "Details Forum"

    Posted 07-02-2019 09:14 AM
    Thank you for sharing the parapet detail, Stephen, for the project in China.  Can you tell me how the constructor installed the rock wool insulation?  It appears that it would would need to be installed prior to installing the cement board sheathing which would expose the insulation to the elements until such time as the sheathing would be installed. I ask because we are regularly challenged by the installers of parapet insulation claiming they cannot install the insulation as detailed due to a lack of access. Thank you again!

    ------------------------------
    Chris Kirschner AIA
    partner
    BDG Architects
    Tampa FL
    ------------------------------



  • 15.  RE: "Details Forum"

    Posted 07-08-2019 12:16 PM




    Sent from my Galaxy Tab E Lite





  • 16.  RE: "Details Forum"

    Posted 07-08-2019 04:50 PM
    Chris, great question. It was a little while ago but from what I recall the contractor staged the parapet work such that the sheathing and weather barrier were installed almost immediately after the insulation to avoid what you describe. This all fell under means and methods of the contractor but they seemed to be fine with the approach. I will tell you that the detailing of the parapet for this project took a considerable amount of energy on everyone's part. Thanks, Stephen.

    ------------------------------
    Stephen Katz AIA
    Gensler - Chicago
    Chicago IL
    ------------------------------



  • 17.  RE: "Details Forum"

    Posted 06-05-2019 07:30 PM
    @Joseph J. Deringer AIA Member Emeritus, I'm enjoying this discussion, but I'm wondering about the goal of posting the detail in this forum.  Is the intent to come up with constructive criticism that will improve the detail that is ultimately posted on the "Details Forum"?  Or is it simply a point of departure for discussing the depicted condition?  TIA for clarifying! ​​​

    ------------------------------
    Richard J. Linsky, AIA, CSI, CDT, NCARB
    Project Architect
    Jacobs/Wyper Architects, LLP
    Philadelphia, PA
    ------------------------------



  • 18.  RE: "Details Forum"

    Posted 06-06-2019 11:48 AM
    Perhaps the parapet detail can serve as an example that we can all comment on and once it has been updated to address the group's comments it can serve as a model for development of other details.  It is not realistic for us to develop a complete set of all possible details, but if there is a set of good, thoroughly thought-through generic details, it would be a good resource for working through the specific details for our projects.

    ------------------------------
    Margaretha Eckhardt AIA, CSI, CCS, LEED AP
    Payette Associates, Inc.
    Boston MA
    ------------------------------



  • 19.  RE: "Details Forum"

    Posted 07-28-2019 05:59 PM
    Yes, the intent of the forum is to post details that we can all comment and refine based on the comments received. The original parapet detail posted, was not intended as the final or best example of how to solve that condition, but an approach to be discussed.

    ------------------------------
    [E. Bradford] [Glellert] [AIA]
    [TDA]
    [Willoughby] [Ohio]
    ------------------------------



  • 20.  RE: "Details Forum"

    Posted 06-06-2019 05:34 PM
    Looking forward to the first draft. Thanks for sharing!

    ------------------------------
    Sarah Gudeman
    Mechanical Engineer
    Morrissey Engineering
    Omaha NE
    ------------------------------